Cas 200 Alfa Laval New Version -

The New CAS 200 — Alfa Laval’s Quiet Revolution

When the first CAS 200 rolled off the line, it was praised for reliability and simplicity. For years, engineers at Alfa Laval listened to customers who needed the same dependability—but smarter, faster, and greener. The new version arrived not with fanfare but with the small, insistent changes that transform everyday work.

7. Conclusion

There is no single “new version” launch event for the CAS 200. Instead, Alfa Laval has continuously upgraded the platform. The current new version (as of 2026) is defined by:

  • Alfa Laval Touch controller with IoT capability.
  • EC fans as standard on most sizes.
  • Low-GWP refrigerant readiness.
  • Modular, service-friendly design.

For operators of older CAS 200 units, the recommended action is to contact Alfa Laval Service for a retrofit assessment – especially if control system faults or high fan energy consumption are already observed. cas 200 alfa laval new version


End of report


5.3. Compliance Benefit

New version helps meet IMO Energy Efficiency Existing Ship Index (EEXI) and Carbon Intensity Indicator (CII) indirectly by reducing auxiliary power consumption (HVAC is a top 3 energy user on most vessels). The New CAS 200 — Alfa Laval’s Quiet

Installation and Retrofitting: Can You Upgrade Your Existing System?

A common question from operators is whether they can simply retrofit parts of the CAS 200 Alfa Laval new version into their old separator frame. The short answer is no.

  • Bowl and spindle: The new rotating assembly is not compatible with the old frame due to different bearing sizes and speed ratings.
  • Control cabinet: You can keep the old mechanical frame but install the new EPC 60 cabinet. However, you will need new wiring for the sensors (flow, temperature, vibration).
  • Alfa Laval’s recommendation: They offer a conversion kit (Part No. 545699-01) that includes a new top part (bowl, hood, and discharge mechanism) fitted to your old base plate. This is the most cost-effective route.

Tip: If your old CAS 200 is more than 12 years old, Alfa Laval advises a full replacement rather than a retrofit, as the cast iron base may have hidden stress cracks. Alfa Laval Touch controller with IoT capability

2.5 Intelligent Alarm Logic

  • Trend Analysis: Predicts gradual oil carryover before alarm threshold is reached.
  • Three-Stage Alarms:
    • Pre-alarm (yellow): Scheduled maintenance recommended.
    • High mist (orange): Reduce load & check separator.
    • Shutdown (red): Automatic engine trip signal (configurable delay: 0–10s).

8. Technical Specifications (New Version)

| Parameter | Value | |-----------|-------| | Supply voltage | 24V DC (18–32V) | | Power consumption | < 20W (panel), < 35W total | | Operating temp | -15°C to +55°C | | Protection class | IP66 front, IP20 rear | | Digital inputs | 16 (24V DC) | | Analog inputs | 8 (4–20mA / PT100) | | Relay outputs | 6 (2A @ 250V AC) | | Certifications | DNV, ABS, LR, BV, CCS |