Digi Sm500 Scale User Manual -
Digi SM-500 Precision Balance: The Complete User & Technical Manual
Cleaning Instructions
- Daily: Wipe the stainless steel platform with a damp cloth and mild detergent.
- Do not submerge the scale or use high-pressure water.
- Do not use acetone, benzene, or abrasive cleaners on the LCD or plastic housing.
Operational Report: Digi SM-500 Scale
Subject: User Manual Summary & Operational Guide Model: Digi SM-500 (Label Printing Scale)
Simple Weighing (Manual Price Entry)
Use this method for items that do not have a preset PLU or for one-off sales. digi sm500 scale user manual
- Place the item on the scale.
- Type the price per kg/lb using the numeric keypad (e.g.,
5,0,0for $5.00). - Press the
PRICEkey (on some models, this step is automatic after entering numbers). - The Total Price will calculate automatically on the screen.
- Press the
PRINTkey to issue a label.
5.3 Changing units
Press UNIT (or MODE) repeatedly to cycle through: Digi SM-500 Precision Balance: The Complete User &
- Grams (g)
- Carats (ct) – 1 ct = 0.2 g
- Ounces (oz) – 1 oz ≈ 28.3495 g
- Troy ounces (ozt)
- Pennyweight (dwt)
- Grains (gn) – on some models
Note: Precision may slightly vary by unit due to rounding. Daily: Wipe the stainless steel platform with a
Section 5: Troubleshooting Common Error Codes
The digi sm500 scale user manual lists several error codes. Here’s what they mean and how to resolve them:
| Error Code | Meaning | Solution |
|------------|---------|----------|
| EEEEE or O-LD | Overload – weight exceeds capacity | Remove weight immediately. Check load cell for damage. |
| Err Z | Zero range error (<-2% or >+2% of capacity) | Remove debris from platform. Press ZERO. Recalibrate if needed. |
| Err C | Calibration error | Repeat calibration with correct weight. Ensure no movement. |
| Lo Bat | Low battery (if battery option installed) | Replace batteries or connect AC adapter. |
| Err 1 | Load cell signal too low | Check load cell cable connection. Load cell may be damaged. |
| UnSt | Unstable environment | Stop air flow, use stable table, wait for vibration to cease. |