Master the Gilbarco SK700: A Guide to Programming and Setup Gilbarco SK700 and its successor, the
, are staples of the modern forecourt, known for their modular design and reliability. However, whether you're performing a fresh installation or troubleshooting a system error, navigating the Programming Manual can be a challenge.
This guide breaks down the essential programming steps and command codes you need to keep your dispensers running smoothly. 1. Accessing Programming Mode
To begin programming, you must access the internal computer head. For higher-level changes (like configuration or calibration), you’ll need to interact with the Sandpiper electronics Security PINs:
Most SK700 units use standard default codes unless changed by the site manager: 2222 (Basic PPU and presets) 1503 (ID and communication settings) 1309 (Calibration and density) 0128 (Master/Cold start access) 2. Essential Command Codes The SK700 uses a Command Code system to navigate its functions. Use the Manager Keypad to enter these codes after logging in. Command Code Updates the Price Per Unit for each grade and side. Assigns the logical Pump Number for POS communication. Cold Start Clears all memory—only used for deep troubleshooting. Clock/Date Sets the dispenser's internal time and date Calibration electronic calibration of the meters. Flow Rates Adjusts the maximum liters per minute 3. Performing a "Cold Start"
If the dispenser has a major logic error or is being repurposed, a Cold Start is required to reset its memory. Safety First: Power down the dispenser. Toggle the Jumper: Locate the Cold Start jumper
on the processor board and move it to the "Cold Start" position. Reapply power. You should see a flashing on the display. Authorize: , enter the master code ( ), and select option (Clear all data).
Power down again, return the jumper to the "Normal" position, and power back up to begin initial configuration. 4. Common Troubleshooting Codes
If your dispenser stops working, look for these common error codes on the display: Pulser Disconnected—check the wiring to the meter.
Emergency Stop Button—ensure the stop button hasn't been accidentally pressed.
POS Communication Lost—the dispenser cannot "talk" to the console.
SK700 Fuel Dispensing Overview | PDF | Corrosion | Internet - Scribd
Gilbarco SK700 programming manual is a technical document used by field service technicians to configure dispenser parameters, perform cold starts, and troubleshoot hardware. Essential Programming Codes
Programming is typically performed via the managerial keypad using specific security levels: Level 0 (0000): Basic access. Level 1 (2222): Set Price Per Unit (PPU) [Command Code 20]. Level 4 (0128): Master access for core system changes. Command Code Options/Action PPU (Price) Select Side (1, 2, or 3 for both) then Grade. Operation Mode 1 = Two-wire (remote); 2 = Standalone. Volume Allocation Set max volume limit per transaction. Pump Beeper Enable or disable the keypad/transaction beeper. Display Test Adjust segment lamp test time (default is 3s). Cold Start & Initial Setup
A cold start is required for major reconfigurations or after replacing the CPU board: Hardware Access: Open the CPU board cover. Toggle Switch: Move the switch to the CAL position. Jumper: Move the jumper to the Cold Start position. Power Up: The display will show a flashing E9.
Enter Codes: Press F1, enter master code 0128, and press Enter.
Basic Parameters: You must set the country code, pump type, pump numbers, and protocol. Troubleshooting Quick Reference Common error codes seen on the unit price display: E1 / E35: Database or configuration error. E5 / E5034: Software cold start executed. E9 / 5035: Hardware cold start jumper is active.
Code 11: Two-wire communication lost between pump and controller. Code 20: Pulser disconnected or not mapped correctly. Code 33: Emergency Stop (E-Stop) button activated.
Detailed error logs can be requested directly from Gilbarco Veeder-Root or specialized repair centers like Kentronics. If you'd like, I can:
Give you the exact steps for a specific code (like changing the PPU).
Provide a deeper breakdown of error codes for a specific issue (e.g., leaks or communication failure).
Help you find a PDF version of a specific sub-manual (like for the Apollo CPU or LPG units). What is the current issue or task you are working on?
6. Pump/Hose Control Parameters
- Set dispenser calibration factors (pulses per volume unit) for each nozzle.
- Configure automatic nozzle shutoff behavior and minimum dispense amounts.
- Set forecourt timers, maximum transaction limits, and stuck nozzle detection thresholds.
- Enable/disable hose specific functions (prepay block, post-pay enable, grade lock).
Finding the Programming Manual
To obtain the Gilbarco SK700 Programming Manual, consider the following options:
- Gilbarco Official Website: You can start by visiting the official Gilbarco website or its parent company's website, such as Veeder-Root. They might have a section for product manuals and documentation.
- Manufacturer's Support: Contact Gilbarco's customer support directly via phone or email. They can guide you on how to access the manual or provide it to you directly.
- Online Repositories: Some online repositories, forums, or communities dedicated to fuel dispenser systems or point-of-sale systems might have shared copies of the manual. However, be cautious when downloading files from unverified sources.
- Documentation Libraries: Look for libraries or databases that specialize in technical manuals and documentation for industrial equipment.
3. Core Sections of the SK700 Programming Manual
A genuine Gilbarco SK700 manual is structured into logical modules. Below is a breakdown of the key chapters you will encounter.
13. Vendor Support & Documentation
- Maintain vendor contact and support contract information.
- Use vendor-supplied manuals for detailed menu trees, error code lists, and firmware procedures.
- Record serial numbers, firmware versions, and configuration exports for support calls.
If you want, I can:
- Generate a printable step-by-step programming checklist tailored for a single SK700 unit (include common menu sequences).
- Produce a short troubleshooting flowchart for calibration and communication errors.
(Optionally invoke related search suggestions...)
Understanding the Gilbarco SK700 Programming Manual The Gilbarco SK700 and its successor, the SK700-II, are among the most reliable and widely used fuel dispensers globally. However, for a station owner or technician, accessing the "brains" of the pump requires a solid understanding of the programming manual and the specific command codes used to configure the unit.
Whether you are performing a new installation or adjusting prices, this guide breaks down the essential elements of the Gilbarco SK700 programming process. 1. Accessing the Programming Mode
To make any changes to the SK700, you must first enter the Service Mode. Unlike consumer electronics, fuel dispensers require a physical or electronic "key" to prevent unauthorized tampering with weights and measures.
The Command Console: Most programming is done via the manager’s keypad or a handheld remote programmer.
Security Switch: Inside the pump head, there is typically a "Calibration" or "Program" switch that must be toggled to allow permanent changes to metrology settings. 2. Navigation and Command Structure
The SK700 uses a Command-Sub-code system. You enter a primary code to select a category (like "Price" or "System Configuration") and then a sub-code to drill down to specific settings. Common Function Codes:
Level 1 (Manager Level): General stats, such as totals and basic price changes.
Level 2 (Technician Level): Configuration of hydraulic types, blend ratios, and vapor recovery settings.
Level 3 (Weights & Measures): Calibration of the meters (requires breaking the physical seal). 3. Key Programming Tasks Unit Price Programming
One of the most frequent uses for the manual is changing the price per litre or gallon. Enter the manager code. Navigate to the Price Change command (usually command 1). Select the specific Grade or Hose. Input the new price and press Enter to confirm. Calibration and Metering
If the pump is dispensing slightly more or less than the display shows, you must calibrate the meter. The SK700 manual outlines the "K-Factor," which is the electronic pulse count per unit of fuel. Adjusting this value ensures the pump remains accurate and legal for trade. Error Code Diagnostics
The programming manual is also a diagnostic tool. When the pump displays a "Fail" message, you can use the command console to pull the Error Log. Common codes include: Error 20: Pulser failure.
Error 31: Communication timeout with the Point of Sale (POS) system. Error 50: Internal memory error. 4. Safety and Compliance Warning
Programming a Gilbarco SK700 is not just a technical task; it is a legal one. In most jurisdictions:
Sealing: Any change to the volume measurement must be reported to local Weights and Measures authorities.
Safety: Always ensure the power is off or the pump is in a safe state before opening the cabinet to access the programming switches.
The Gilbarco SK700 Programming Manual is an indispensable tool for maintaining fuel accuracy and operational efficiency. While basic price changes can be done by a manager, complex configuration and calibration should always be handled by a certified technician to ensure compliance with safety and trade regulations.
Programming the Gilbarco SK700 and SK700-II dispensers involves using a manager’s keypad for basic setup parameters, such as pump type, protocol, and pricing, following a necessary "Cold Start" procedure to clear memory. Key technical procedures, including CAL switch positioning and USB configuration, are outlined in official documentation, such as the Gilbarco Installation & Commissioning Manual. For comprehensive technical instructions, reference the Kentronics SK700-2 Cold Start Guide.